PARAM, ELASRLMT
Bulk Data Entry Issues a WARNING when the stiffness value for rotational components on the CELAS2/CELAS4 or PELAS entry exceeds the specified limit (ELASRLMT).
Comments
- This check is overridden when PARAM, ELASSTIF is used to control the maximum stiffness value.