PCONVLIB

Bulk Data Entry Defines the external function to be called to calculate time and temperature-dependent free-convection coefficient in a convection element.

Format

(1) (2) (3) (4) (5) (6) (7) (8) (9) (10)
PCONVLIB PID GROUP FUNCT

Definitions

Field Contents SI Unit Example
PID Convection property identification number. 1

No default (Integer > 0)

GROUP Defines the shared/dynamic library to be used.

Refers to an existing LOADLIB entry in the input deck.

No default (Character)

FUNCT Defines the external function to be used.

No default (Character)

Comments

  1. The property identification number (PID) must match the corresponding identification number on the PCONV entry.