MBMNT

Bulk Data Entry Defines a constant moment at a grid point by specifying a vector.

Format

(1) (2) (3) (4) (5) (6) (7) (8) (9) (10)
MBMNT SID G1 CID M G3/N1 N2 N3 G2

Example

(1) (2) (3) (4) (5) (6) (7) (8) (9) (10)
MBMNT 3 345 100.0 0.0 1.0 0.0

Definitions

Field Contents SI Unit Example
SID Load set identification number.

No default (Integer > 0)

G1 Grid point identification number where the action force is applied.

No default (Integer > 0)

CID Coordinate system identification number. Blank or 0 infer the basic coordinate system.

Default = 0 (Integer ≥ 0, or blank)

M Moment magnitude.

No default (Real)

G3 Grid point identification number to optionally supply N1, N2, N3 in conjunction with G1.

(Integer > 0)

N1,N2,N3 Defines the direction of the force vector. At least one of the vector components must be non-zero.

Default = 0.0 (Real)

G2 Grid point identification number where the reaction force is applied. If blank or zero, the force is an action-only force.

Default = 0 (Integer ≥ 0)

Comments

  1. This card is represented as a moment load in HyperMesh.