Bulk Data Entry Defines an expression scalar moment on two grid points along the specified vector.

Format

(1) (2) (3) (4) (5) (6) (7) (8) (9) (10)
MBSMNTE SID G1 G2 EID Vx Vy Vz

Example

(1) (2) (3) (4) (5) (6) (7) (8) (9) (10)
MBSMNTE 3 345 346 2 0 1.0 1.0

Definitions

Field Contents SI Unit Example
SID Load set identification number.

No default (Integer > 0)

G1 Grid point identification number.

No default (Integer > 0)

G2 Grid point identification number.

No default (Integer > 0)

EID Expression identification number of the MBVAR entry.

No default (Integer > 0)

G3 Grid point identification number to optionally supply Vx, Vy, and Vz in conjunction with G1.

(Integer > 0)

Vx X component of Vector V
Vy Y component of Vector V
Vz Z component of Vector V

Comments

  1. MBSMNTE applies a scalar action-reaction moment on G1 and G2 along the vector defined by Vx, Vy, and Vz.
  2. The action moment is applied to G1 and the reaction moment is applied to G2.
  3. Right hand rule defines the positive moment.