PARAM, ALLFT

Bulk Data Entry This parameter is used to control the output from multiple failure theories to the H3D and .cstr files.

Parameter Values Description
ALLFT <YES, NO>
Defaults:
  1. When the parameter is not present in the deck, then multiple failure output is not activated.
  2. The Values field cannot be blank.
YES
Multiple Failure Theory output is activated and all supported failure theory output is calculated for the given model. For instance, if only HILL theory is identified specifically in the model, the other failure theory output, including HILL are printed. Currently, ALLFT output is supported for H3D and .cstr files.
NO
Multiple Failure Theory output is not active.

Comments

  1. PUCK failure is output only if the corresponding MATF material information for PUCK is present.