*dummyplacerootbodytopoint
Moves a dummy from a source point to a target point.
Syntax
*dummyplacerootbodytopoint name sx sy sz tx ty tz tolerance
Type
HyperMesh Tcl Modify Command
Description
Moves a dummy from a source point to a target point.
The mechanism must have the enabled flag set to true for this to be possible.
Inputs
- name
- The name of the root body of the dummy.
- sx
- The x-coordinate of the source point. This is usually the x-coordinate of the H-Point of the dummy.
- sy
- The y-coordinate of the source point. This is usually the y-coordinate of the H-Point of the dummy.
- sz
- The z-coordinate of the source point. This is usually the z-coordinate of the H-Point of the dummy.
- tx
- The x-coordinate of the target point.
- ty
- The y-coordinate of the target point.
- tz
- The z-coordinate of the target point.
- tolerance
- The tolerance allowed during the placement.
Example
To move a dummy with root body named "Pelvis Angle Gauge" from (0,0,0) to (150,100,200):
*dummyplacerootbodytopoint "Pelvis Angle Gauge" 0 0 0 150 100 200 0.001
Errors
Incorrect usage results in a Tcl error. To detect
errors, you can use the catch
command:
if { [ catch {command_name...} ] } {
# Handle error
}
Version History
14.0.120