*CE_ConnectorAreaMeshWithDetails
Meshes area connectors and updates the width and offset stored on the connector.
Syntax
*CE_ConnectorAreaMeshWithDetails mark_id element_size element_type element_type2 link_opposite_edges size_control skew_control edge_mesh_algorithm min_size max_size chordal_deviation max_angle area_width area_offset
Type
HyperMesh Tcl Modify Command
Description
Meshes area connectors and updates the width and offset stored on the connector.
Inputs
- mark_id
- The ID of the mark of area connectors. Valid values are 1 and 2.
- element_size
- The element size.
- element_type
- The element type for mapped meshing algorithms:
- element_type2
- The element type for free meshing algorithms:
- link_opposite_edges
- 0 - Do not link
- size_control
- 0 - Off
- skew_control
- 0 - Off
- edge_mesh_algorithm
- 0 - Standard
- min_size
- The minimum element size when edge_mesh_algorithm is 1.
- max_size
- The maximum element size when edge_mesh_algorithm is 1.
- chordal_deviation
- The chordal deviation value when edge_mesh_algorithm is 1.
- max_angle
- The maximum angle between edges when edge_mesh_algorithm is 1.
- area_width
- The new width value.
- area_offset
- The new offset value.
Examples
To update area connector 10 with width 2.0 and mesh it with a default edge size of 1.0:
*createmark connectors 1 10
* CE_ConnectorAreaMeshWithDetails 1 1.0 1 1 1 0 0 0 0 0 0 0 2.0 0.0
Errors
Incorrect usage results in a Tcl error. To detect
errors, you can use the catch
command:
if { [ catch {command_name...} ] } {
# Handle error
}
Version History
2021