*convertthermalloads
Converts thermal loads from one solver to another.
Syntax
*convertthermalloads source_solver target_solver source_card target_card
Type
HyperMesh Tcl Modify Command
Description
This command converts thermal loads from one solver to another. Currently it converts *FILM and *SFILM loads from Abaqus to PCONV group in OptiStruct. It should be used in conjunction with *setoption retain_loads. This command works when the OptiStruct template is loaded after the model is imported in Abaqus.
Inputs
- source_solver
- The source solver name. Must be set to Abaqus.
- target_solver
- The target solver name. Must be set to OptiStruct.
- source_card
- The source card to convert from. Can be either FILM or SFILM.
- target_card
- The target card to convert to. Must be set to PCONV.
Example
To convert FILM to PCONV:
*setoption retain_loads=1
*convertthermalloads Abaqus Optistruct FILM PCONV
Errors
Incorrect usage results in a Tcl error. To detect
errors, you can use the catch
command:
if { [ catch {command_name...} ] } {
# Handle error
}
Version History
14.0.130