*CE_ConnectorCreateByList
Creates a certain style of connector at locations specified by a list, with certain rules and details.
Syntax
*CE_ConnectorCreateByList entity_type list_id ce_style num_links link_entity_type link_mark_id string_array number_of_strings
Type
HyperMesh Tcl Modify Command
Description
Creates a certain style of connector at locations specified by a list, with certain rules and details.
Inputs
- entity_type
- The entity type that specifies the location to create connectors. Valid values are:
- list_id
- The ID of the list containing the entities. Valid values are 1 and 2.
- ce_style
- The style of connectors to create. Valid values are area, bolt, seam and spot.
- num_links
- The number of links to use.
- link_entity_type
- The type of entity to create links for. Valid values are comps and surfs.
- link_mark_id
- The ID of the mark containing the link entities. Valid values are 1 and 2.
- string_array
- The ID of the string array that contains the additional input parameters. The string
array is created using the *createstringarray command. This should
always be set to 1. Valid parameters include:
- area_offset=<value>
- Offset area connectors created from node or line lists from the selected location by this value. Default 0.0.
- area_width=<value>
- Width of area connectors created from node or line lists. Default 1.0.
- line_density=<value>
- The density for spot or seam connectors on lines. Default 0.0.
- line_offset=<value>
- Offset value from the ends of the line for spot or seam connectors on lines. Default 0.0.
- line_offset_flag=<value>
- 0 - Do not offset connectors (default).
- line_spacing=<value>
- The spacing for spot or seam connectors on lines. Default 1.0.
- link_elems_geom=<value>
- Specifies whether to connect elements (elems) or geometry (geom). Default is elems.
- link_rule=<value>
- The link rule. Valid values are now, at_fe_realize or none. Default is none.
- relink_rule=<value>
- The relink rule. Valid values are id, name or none. Default is none.
- seam_area_group=<value>
- Group flag for seam or area connector.
- tol=<value>
- Add entities as links only within this distance of the specified location. Default 0.0.
- tol_flag=<value>
- 0 - Do not offset tol (default).
- number_of_strings
- Integer indicating the size (number of strings) in the string array created using *createstringarray.
Examples
To create a seam connector at the location of line 10 to connect component 3 and 4 using a
tolerance of
6.0:
*createlist lines 1 10
*createmark components 2 3 4
*createstringarray 5 "link_elems_geom=elems" "link_rule=now" "relink_rule=none" "tol_flag=1" "tol=6.000000"
*CE_ConnectorCreateByList lines 1 "seam" 2 comps 2 1 5
Errors
Incorrect usage results in a Tcl error. To detect
errors, you can use the catch
command:
if { [ catch {command_name...} ] } {
# Handle error
}