Embedded Category: F280x
Block Category: TI 32-bit DMC
The maximum input frequency is normalized to 1. Block input (fin) is a fraction of the maximum frequency.
Operating Mode Availability
• Simulation mode: YES
• C code generation mode: YES
The V/Hz Profile Generator block generates an output command voltage for a specific input command frequency according to the specified V/Hz profile. This is used for variable speed implementation of AC induction motor drives.
High Frequency Point: Indicates HFP.
Low Frequency Point: Indicates LFP.
Slope of Volts/Hertz Profile: Indicates slope.
Voltage at HFP: Indicates VHFP.