Transformer

A cable transformer component.

Example

application = cf.Application.GetInstance()
project = application:Load({FEKO_HOME..[[/shared/Resources/Automation/Cables.cfx]]})

    -- Add a transformer

cableHarness = project.Contents.CableHarnesses["CableHarness1"]
inductor1Terminal1 = cableHarness.Connectors["CableConnector1"].Pins["Pin1"].Terminal
inductor1Terminal2 = cableHarness.Connectors["CableConnector1"].Pins["Pin2"].Terminal
inductor2Terminal1 = cableHarness.Connectors["CableConnector2"].Pins["Pin1"].Terminal
inductor2Terminal2 = cableHarness.Connectors["CableConnector2"].Pins["Pin2"].Terminal
transformer = cableHarness.CableSchematic.Components:AddTransformer(
    inductor1Terminal1, inductor1Terminal2, inductor2Terminal1, inductor2Terminal2, 1e-6, 2e-6)

    -- Change the transformers coupling coefficient

cableHarness.CableSchematic.Components["T1"].CouplingCoefficient = 0.8

Inheritance

The Transformer object is derived from the Object object.

Usage locations

The Transformer object can be accessed from the following locations:

Property List

CoupledInductor1
The value of coupled inductor 1 in Henry. (Read/Write ParametricExpression)
CoupledInductor2
The value of coupled inductor 2 in Henry. (Read/Write ParametricExpression)
CouplingCoefficient
The coupling coefficient between the two inductors as a ratio. (Read/Write ParametricExpression)
CurrentProbeEnabled
True if a current probe must be applied to the component. (Read/Write boolean)
Label
The object label. (Read/Write string)
PhaseDefinition
The phase orientation definition between the two coupled inductors. (Read/Write CableTransformerPhaseDefinitionEnum)
Schematic
The schematic associated with this item. (Read only Schematic)
SchematicLocation
The location of the item on the schematic. (Read only GridLocation)
SchematicRotation
The rotation of the item on the schematic. (Read only SymbolRotationEnum)
Terminals
The schematic terminals on this item. (Read only List of Terminal)
Type
The object type string. (Read only string)
VoltageProbeEnabled
True if a current probe must be applied to the component. (Read/Write boolean)

Method List

Delete ()
Deletes the entity.
Duplicate ()
Duplicates the entity. (Returns a Object object.)
GetProperties ()
Returns a table of properties representing the state of the object. The properties table can be used with the SetProperties method to change multiple properties of the object in one step. (Returns a table object.)
RotateSchematicSymbol ()
Rotates the item on the schematic.
SetProperties (properties Object)
Modifies the state of the object using the provided table of properties. This method is used to modify multiple properties of the object in a single step.
SetSchematicLocation (location GridLocation)
Sets the location of the item on the schematic.
SetSchematicRotation (rotation SymbolRotationEnum)
Sets the rotation of the item on the schematic.

Static Function List

GetDefaultProperties ()
Creates a table containing the default settings to create an object. (Returns a table object.)

Property Details

CoupledInductor1
The value of coupled inductor 1 in Henry.
Type
ParametricExpression
Access
Read/Write
CoupledInductor2
The value of coupled inductor 2 in Henry.
Type
ParametricExpression
Access
Read/Write
CouplingCoefficient
The coupling coefficient between the two inductors as a ratio.
Type
ParametricExpression
Access
Read/Write
CurrentProbeEnabled
True if a current probe must be applied to the component.
Type
boolean
Access
Read/Write
Label
The object label.
Type
string
Access
Read/Write
PhaseDefinition
The phase orientation definition between the two coupled inductors.
Type
CableTransformerPhaseDefinitionEnum
Access
Read/Write
Schematic
The schematic associated with this item.
Type
Schematic
Access
Read only
SchematicLocation
The location of the item on the schematic.
Type
GridLocation
Access
Read only
SchematicRotation
The rotation of the item on the schematic.
Type
SymbolRotationEnum
Access
Read only
Terminals
The schematic terminals on this item.
Access
Read only
Type
The object type string.
Type
string
Access
Read only
VoltageProbeEnabled
True if a current probe must be applied to the component.
Type
boolean
Access
Read/Write

Method Details

Delete ()
Deletes the entity.
Duplicate ()
Duplicates the entity.
Return
Object
The new (duplicated) entity.
GetProperties ()
Returns a table of properties representing the state of the object. The properties table can be used with the SetProperties method to change multiple properties of the object in one step.
Return
table
A table defining the properties.
RotateSchematicSymbol ()
Rotates the item on the schematic.
SetProperties (properties Object)
Modifies the state of the object using the provided table of properties. This method is used to modify multiple properties of the object in a single step.
Input Parameters
properties(Object)
A table of properties defining the new state of the object.
SetSchematicLocation (location GridLocation)
Sets the location of the item on the schematic.
Input Parameters
location(GridLocation)
The schematic location the item should be moved to.
SetSchematicRotation (rotation SymbolRotationEnum)
Sets the rotation of the item on the schematic.
Input Parameters
rotation(SymbolRotationEnum)
The rotation setting.

Static Function Details

GetDefaultProperties ()
Creates a table containing the default settings to create an object.
Return
table
A table containing the default properties.