CableNonConductingElementCrossSection
A non conducting element cable cross section.
Example
application = cf.Application.GetInstance() project = application:Load({FEKO_HOME..[[/shared/Resources/Automation/Cables.cfx]]}) -- Add a non-conducting element cross section element = project.Definitions.Cables.CrossSections:AddNonConductingElement( project.Definitions.Media.Dielectric["Insulation"], 0.002) -- Modify the label of the cross section element.Label = "Spacer"
Inheritance
The CableNonConductingElementCrossSection object is derived from the CableCrossSection object.
Usage locations
The CableNonConductingElementCrossSection object can be accessed from the following locations:
- Methods
- CableCrossSectionCollection collection has method AddNonConductingElement(table).
- CableCrossSectionCollection collection has method AddNonConductingElement(Medium, Expression).
Property List
- CablePerUnitLengthAccuracy
- Select a higher accuracy when calculating cable per-unit-length parameters. (Read/Write CablePerUnitLengthAccuracyEnum)
- FibreMedium
- The fibre medium. (Read/Write Medium)
- FibreRadius
- The fibre radius. (Read/Write ParametricExpression)
- Label
- The object label. (Read/Write string)
- Type
- The object type string. (Read only string)
Method List
- Delete ()
- Deletes the entity.
- Duplicate ()
- Duplicates the entity. (Returns a Object object.)
- GetProperties ()
- Returns a table of properties representing the state of the object. The properties table can be used with the SetProperties method to change multiple properties of the object in one step. (Returns a table object.)
- SetProperties (properties Object)
- Modifies the state of the object using the provided table of properties. This method is used to modify multiple properties of the object in a single step.
Static Function List
- GetDefaultProperties ()
- Creates a table containing the default settings to create an object. (Returns a table object.)
Property Details
- CablePerUnitLengthAccuracy
- Select a higher accuracy when calculating cable per-unit-length parameters.
- Type
- CablePerUnitLengthAccuracyEnum
- Access
- Read/Write
- FibreMedium
- The fibre medium.
- Type
- Medium
- Access
- Read/Write
- FibreRadius
- The fibre radius.
- Type
- ParametricExpression
- Access
- Read/Write
- Label
- The object label.
- Type
- string
- Access
- Read/Write
- Type
- The object type string.
- Type
- string
- Access
- Read only
Method Details
- Delete ()
- Deletes the entity.
- Duplicate ()
- Duplicates the entity.
- Return
- Object
- The new (duplicated) entity.
- GetProperties ()
- Returns a table of properties representing the state of the object. The properties table can be used with the SetProperties method to change multiple properties of the object in one step.
- Return
- table
- A table defining the properties.
- SetProperties (properties Object)
- Modifies the state of the object using the provided table of properties. This method is used to modify multiple properties of the object in a single step.
- Input Parameters
- properties(Object)
- A table of properties defining the new state of the object.
Static Function Details
- GetDefaultProperties ()
- Creates a table containing the default settings to create an object.
- Return
- table
- A table containing the default properties.