ExcitationStoredData

Stored excitation results.

Example

app = pf.GetApplication()
app:NewProject()
app:OpenFile(FEKO_HOME..[[/shared/Resources/Automation/startup.fek]])

    -- Retrieve the 'ExcitationData' called 'VoltageSource'

excitationData = app.Models[1].Configurations[1].Excitations["VoltageSource"]

    -- Store a copy of the excitation data.
    
storedData = excitationData:GetDataSet():StoreData(pf.Enums.StoredDataTypeEnum.Source)

Inheritance

The ExcitationStoredData object is derived from the ResultData object.

Property List

ContinuousFrequencyAxis
Continuous frequency axis exists. (Read only boolean)
Label
The object label. (Read/Write string)
Type
The object type string. (Read only string)

Method List

Delete ()
Delete the stored data.
ExportData (filename string, frequencyunit FrequencyUnitEnum, networkparametertype NetworkParameterTypeEnum, networkparameterformat NetworkParameterFormatEnum, referenceimpedance number, samples number)
Export the result S-parameter data to the specified Touchstone file.
GetDataSet ()
Returns a data set containing the source values. (Returns a DataSet object.)
GetDataSet (samplePoints number)
Returns a data set containing the source values. (Returns a DataSet object.)
GetDataSet (startFrequency number, endFrequency number, samplePoints number)
Returns a data set containing the source values. (Returns a DataSet object.)

Property Details

ContinuousFrequencyAxis
Continuous frequency axis exists.
Type
boolean
Access
Read only
Label
The object label.
Type
string
Access
Read/Write
Type
The object type string.
Type
string
Access
Read only

Method Details

Delete ()
Delete the stored data.
ExportData (filename string, frequencyunit FrequencyUnitEnum, networkparametertype NetworkParameterTypeEnum, networkparameterformat NetworkParameterFormatEnum, referenceimpedance number, samples number)
Export the result S-parameter data to the specified Touchstone file.
Input Parameters
filename(string)
The name of the exported data file without its extension.
frequencyunit(FrequencyUnitEnum)
The frequency unit specified by the FrequencyUnitEnum, e.g. Hz, kHz, GHz, etc.
networkparametertype(NetworkParameterTypeEnum)
The network parameter type specified by the NetworkParameterTypeEnum, e.g. Scattering, Admittance or Impedance.
networkparameterformat(NetworkParameterFormatEnum)
The network parameter format specified by the NetworkParameterFormatEnum, e.g. DB, MA or RI.
referenceimpedance(number)
Specify the reference impedance.
samples(number)
The number of samples for continuous data. This value will be ignored if the data is discrete.
GetDataSet ()
Returns a data set containing the source values.
Return
DataSet
The data set containing the source values.
GetDataSet (samplePoints number)
Returns a data set containing the source values.
Input Parameters
samplePoints(number)
The number of sample points used to sample the continuous frequency axis.
Return
DataSet
The data set containing the source values.
GetDataSet (startFrequency number, endFrequency number, samplePoints number)
Returns a data set containing the source values.
Input Parameters
startFrequency(number)
The start frequency used to sample the continuous frequency axis.
endFrequency(number)
The end frequency used to sample the continuous frequency axis.
samplePoints(number)
The number of sample points used to sample the continuous frequency axis.
Return
DataSet