Sub Board Misarrangement

Check if single boards have the same distance to panel or have placing type.

In panel design, the single boards incorrect position can cause difficulties in the manufacturing process.

The Sub Board Misarrangment dialog contains the following sections:
  • Option
    • Tolerance between Distance Values: Give the tolerance value. While measuring distance, measuring results under the given tolerance will be treated as equal values.
  • Checking:
    • Check Distance between A and A-1, B and B-1, C and C-1, F and F-1: If the same single boards are placed, check the single board edge to the panel board outline.
    • Check Distance between A and F, B and C, D and D-1: If different types of single boards are placed, check the single board edge to panel board outline.
    • Check Distance between E and E-1: If different types of single boards are placed, check the single board placed distance.