AOI-AXI

Checks components on the board that obstruct the field of vision by the height of specific parts.

Figure 1.


More detailed information:
  • Board Direction Definition: Decide the board's placement status using the soldering mark or by defining the soldering direction.
    • Soldering-Mark Component Group: Define the soldering mark. Use if it is registered as a group of components.
      • Mark Direction: Define the mark’s direction and the soldering direction.
    • Soldering Direction: Define the direction of the board without using soldering-mark case.
  • Checking:
    • Item: Specify the item name.
    • Target Component: Set the target components from the component group list.
    • Camera Angle: Set the tilt of the camera.
    • Projection: Select the camera projection direction.
      Figure 2.


    • Victim Component: Set the target components from the component group list.
    • Measure Base: Set the victim component measurement base.