*CONTROL_TERMINATION

LS-DYNA Input Interface KeywordThis keyword defines the conditions to stop a running simulation.

Format

(1) (2) (3) (4) (5) (6) (7) (8)
*CONTROL_TERMINATION
ENDTIME ENDENG ENDMASS

Definition

Field Contents SI Unit Example
ENDTIME Simulation end time.

(Real)

[ s ]
ENDENG Energy error in percent which will cause the simulation to stop.

(Real)

ENDMASS Mass error in percent which will cause the simulation to stop.

(Real)

Comments

  1. This keyword maps to /RUN and /STOP.