/SENSOR/VEL
Block Format Keyword Describes the sensor activated when the velocity of the chosen node reaches the prescribed limit value.
Format
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | (10) | 
|---|---|---|---|---|---|---|---|---|---|
| /SENSOR/VEL/sens_ID/unit_ID | |||||||||
| sens_title | |||||||||
| Tdelay | |||||||||
| node_ID | Vmax | Fcut | |||||||
Definition
| Field | Contents | SI Unit Example | 
|---|---|---|
| sens_ID | Sensor
                                        identifier. (Integer, maximum 10 digits)  | 
                                |
| unit_ID | (Optional) Unit identifier. (Integer, maximum 10 digits)  | 
                                |
| sens_title | Sensor
                                        title. (Character, maximum 100 characters)  | 
                                |
| Tdelay | Time delay. Default = 0.0 (Real)  | 
                                |
| node_ID | Reference node
                                        identifier. (Integer)  | 
                                |
| Vmax | Max velocity.
                                         (Real)  | 
                                |
| Fcut | Filtering frequency of
                                    low pass filter for nodal velocity. (Real)  | 
                                
Comments
- The sensor is activated when nodal velocity is greater than Vmax and after the time Tdelay.