Polymer PTC
This item tracks the voltage and signal lines in the circuit, calculates the voltage value of each net, and checks whether the all polymer PTC connected to the net is within the allowable voltage range.

Figure 1.
- Component: Select Polymer PTC component group to be checked.
- Power Net: Select power net group to which Polymer PTC components are connected.
- Ground Net: Select ground net group to which Polymer PTC components are connected.
- Working
Voltage Check: Set the allowable working voltage of this component. You can
set this by entering the allowable value directly or select the property
name which contain allowable working voltage value. You can also assign
tolerance of this check.
Figure 2.
Stress Test Option
Set whether passive components are considered short or open when navigating signals and power lines.