Defining Calculation Requests
Define the calculation requests in CADFEKO.
-
Define far field data.
- Number of theta points: 37
- Number of phi points: 73
- File name: Browse for the .ffe file
Tip: Click on Field/Current data on the Construct tab to find all the field data types. Select Define Far Field Data. -
Import the spherical mode data from file.
- File name: Browse for the .sph file.
Define near field data.
-
Select Define Near Field Data.
-
Create a far field receiving antenna request.
-
Create a spherical modes receiving antenna request.
-
Create a near field receiving antenna request.
- On the General tab select Combine individual faces
- Field data: NearFieldData1
-
Set the radiated power to 100W.
Tip: To set the radiated power, on the Source/Load tab select Power and select the option Total source power (no mismatch).