Structural Thermal
Structural analysis linked to steady state, transient thermal, thermal imported, or temperature load can be created using the Structural Thermal Workbench.
Thermal loads can be applied via linking to existing thermal analysis or by applying
uniform temperature change to all or specific parts. For more information, refer to
Thermal Load in the Boundary
Conditions
section.
Note: In SimSolid,
when a structural analysis is linked to a thermal analysis, the reported strain
results represent the mechanical strains only. The thermal strain
component is not calculated or outputted. This convention should be kept
in mind when validating SimSolid
results; comparable results are achieved when comparing the directional
mechanical strains from SimSolid
against the purely mechanical strain data from other
solvers.