Define Wall Model

By default, parts have Wall Model properties associated with it.

  1. From the Property Editor, define Wall Model parameters:
    1. Enable the Override checkbox to specify a different wall model.
    2. Select a coupling type.
    3. Enter a value for the intensity.
      Restriction: Only available for One Way coupling type.
  2. Enter a value for the roughness.
    Restriction: Enabled for wheels and belts. Only available for Adaptive Two Way coupling type.
    Tip: If you select the entire model in the Model Browser, you can set Adaptive Two Way to all parts.