Twisted conductors and wires
While defining the coil in the design / Winding area, it is possible to twist the wires inside the conductors between the forward and return sections of the coil. It is also possible to twist the conductors between the forward and return sections of the coil.
It is possible to twist both the wires inside the coil and the conductors between the forward and return sections of the coil.
The four illustrations of what it is possible to do are presented below.
|
Neither the wires nor the conductors are twisted |
|
The wires are twisted inside the conductors. The direction of the gradated conductor color indicates the orientation of the twist. |
|
The conductors are twisted between the forward and return sections of the coil. The conductor colors indicate the position of conductors |
|
The wires are twisted inside the conductors and the conductors are twisted between the forward and return sections of the coil. |