Output Control
This Panel Consists of settings that controls the out files getting generated.
Parameter | Description |
Convergence History Write Out Options |
Controls the Convergence History output in “convhist_fi.out” file 0: reduced residual items for output (writes Convergence History for every 10 iterations) 1: standard residual items (Default value = 1) |
Write Result File in XML Format |
Controls printout of XML file. This data file is in XML format and contains data that might be written to the “.res” file plus some key input data. Users writing post processing tools are encouraged to get their data from this file rather than the “.res” file. 0: Do not write a for046.dat file. 1: Write a standard for046.dat file. (Default value = 0) |
Write database with Results appended |
Controls printout of “*.rst.flo” file. This file contains a database version of the model with solution post-data appended. 0: Do not write a “*.rst.flo” file. 1: Write a “*.rst.flo” file. (Default value = 1) |
Write Fluid Property File |
Controls printout of “*.prop” file. This file contains information about the resultant working fluid properties at each chamber. 0: Do not write a “*.prop” file. 1: Write a “*.prop” file. (Default value = 1) |
Write Result File in SI Units | Prints the results in SI unit system for “*.res” files |
Screen Output Iteration Interval | Controls the Screen Output Printing Intervals |
Model Debug Level |
Extra output print level 0: no extra output, 1: increase output amount |
Write Convergence Monitor file | Writes Convergence Monitor file |