Frame

Type of frame

The tools available in the housing tab allow defining the frame topology.

Three choices are available to define this topology: None, Circular or Square.

By default, housing type is set to “None”. There is no frame.
Important: When “None” is selected, accesses to External cooling and Internal cooling environments are locked.


Frame type available
1 Default setting : Housing type is « None ». The machine has no frame.
2 Button to select a Circular shape frame.
3 Button to select a Square shape frame.
4 Icon to export frame data into *.txt or *.xlsx files.


Circular shape frame design area
1 Radial view of the motor, including the housing topology and dimensions.
2 Axial view of the motor, including the housing topology and dimensions.
3 Selected button to set a circular shape frame.
4 User input parameters to define the frame dimensions. For more information see below.
5 Button to restore default input values.
6 Button to apply inputs. Pressing the enter key twice applies inputs too.
7 Icon to export frame data into *.txt or *.xlsx files.


User input parameters to define frame dimensions in the axial view
1

Thickness of the frame. Allowed range of values ]0, 50] mm.

2 Connection side (C.S.) is identified by yellow lightning.
3

Connection side extension. Allowed range of values [0, 20000] mm.

4

Connection side – End-plate thickness. Allowed range of values [0, 50] mm.

5

Opposite connection side extension. Allowed range of values [0, 20000] mm.

6

Opposite connection side – End-plate thickness. Allowed range of values [0, 50] mm.

Combination between lamination outer shape and frame types

Frame type
None Circular Square

Lamination

Outer shape

None ν ν ν
Circular ν ν ν
Square ν Not possible ν






Circular shape lamination & Circular shape frame Circular shape lamination & Square shape frame Square shape lamination & Square shape frame