Assign points to warnings in various check items differently.
With the use of this point system, you may be able to judge a quality level of PCB
design. A lower point indicates a better design while a higher point indicates that
the design may have a quality issue.
-
DFE Total Limit Point: Assign total point with a number.
If the sum of sub-item’s point is greater than this value, the final status
will be changed to No Good.
-
Check Item Limit Point: Assign each item’s status type and point limit.
-
Item: Show item name.
-
Sub Item: Show sub-items name.
-
Status: View status of the list item.
- Warning: The result will be Warning regardless of the error count or
point.
- Limit: If error count*point is less than Limit, the final status is
changed to Warning.
- If error count*point is equal or greater than Limit, the final status is
changed to No Good.
- Error: The final status is changed to No Good, if any one error
occurs.
-
Point: View assigned point for each error.
-
Limit: View the limit point for each sub-item.