Siemens PADS
You can export Siemens PADS design to an ASCII file, *.asc. Depending on the ASCII version of PowerPCB, they might be different, but PollEx PCB will support every version of them.
- Extract ASCII file from Siemens PADS.
-
From the menu bar, click .
The Import from Siemens PADS dialog opens and contains the following sections:
- Layer Set-Up: Layer Setting is optional. Specify artwork layer name per
each menu.
- COC Top/bottom: PollEx DFM will use these layers’ data for measure base.
- Board Outline: If there is the specific layer for board contour, give that layer name. This layer will be transferred to layer number 21 in PDB structure.
- Drill Layer: If there is the specific layer for drill, give that layer name. This layer will be transferred to layer number 22 in PDB structure.
- Solder Mask To/Bottom: Specify the Solder Mask layer for top and bottom layers.
- Metal Mask Top/Bottom: Specify the Metal Mask layer for top and bottom layers.
- Silk Top/Bottom: Specify the Silk layer for top and bottom layers.
- Signal Layer in Part Section: In footprint definition, enable this checkbox if object layer is signal layer.
- Signal Layer in Line Data Section: In board figure definition, enable this checkbox if object layer is signal.
- Level 0 is Board Outline: Enable this checkbox if layer level 0 is board contour layer.
- Allow Broken Component: Enable this checkbox if Broken Component is used.
- COC of 0 Line Width: Enable this checkbox if line width of COC as 0.
- CAM Pad Over Size (Solder, Paste): Enable this checkbox if solder mask definition is recorded in CAM.
- Generate Teardrops: This option is used automatically generated teardrop shape at PAD and Via.
- Remove Duplicated Segments: Enable this checkbox to remove duplicated segments.
- Apply to Environment Setting: Apply settings to the environment setting.
- PADS ASCII File (*.asc): Select the target ASCII files *.asc to import.
- Layer Set-Up: Layer Setting is optional. Specify artwork layer name per
each menu.