Device Model Files: Specify/register the IC models in the form of IBIS, SPICE,
HSPICE, Linear Device, S/Y/Z Parameters, and RLC Package Parasitic for signal
and power integrity simulations.
Passive Component Data: Specify passive part models in the form of RLC, SPICE,
and S/Y/Z Parameters for signal and power integrity simulations.
Power Rails: Specify the power rail properties for power integrity
simulation.
Package Thermal: Specify the package thermal properties for thermal
analysis.
Package Pin Parasitic Modeler: Use for defining complex package pin RLC
parasitic models for signal and power integrity simulations.
Linear Device Modeler: Use for defining simple linear I/O device models for IC
pins for signal and power integrity simulations.
Click Package Thermal. The Package
Thermal dialog displays. Define thermal properties of a component
part, such as maximum power dissipation of the device and compact package
thermal model data.
Max power dissipation: The device maximum power dissipation.
Max operating temperature: The device maximum operating temperature
allowed.
Min operating temperature: The device minimum operating temperature
allowed.
Package Geometry: The package geometry values. If you do not enter them,
default values are used for thermal analysis.
Compact Thermal Model: PollEx Thermal supports Two-Resistor Model and
DELPHI Model. A DELPHI model is more complex than a Two-Resistor model
and harder to obtain. Click Model Data. The
Two-Resistor dialog displays.
Junction-to-case and Junction-to-board thermal resistance values are
automatically filled with default values based on the part's Package Type
assigned in Analysis Part Setup. You can replace the default values with more
accurate values, if available.