Version 3.2.3, 2019-01-23
- Fixed propagation of excitation leakage factor, see #2403
- Added model of electrical excited synchronous machines, starting direct on line, see #2388
- Unified communication interval, see #2279
- Unified simulation tolerances, see #2278
- Added more examples from Machines.Examples, see #2276
- Replace wrong permeance image in documentation according to #2208
- Added obsolete annotation to SymmetricMultiPhaseCageWinding_obsolete and SaliencyCageWinding_obsolete, see #1536
- Updated documentation of Short, Idle and PermanentMagnet
- Added new components:
- Removed parameter text from icon layer for reluctance and permeance model
- Restructured cage models with reluctance instead of inductance model according to ticket #1536;the re-structuring of the model required to change the initial conditions of the included examples, since the number of rotor states is reduced by new implementation
- Some more bug fixes according to#1226,since not all reference orientations have been correct
- Added variables for magnitude and argument of complex magnetic potential difference and flux, see#1405
Version 3.2.1, 2013-07-31
- Bug fix of wrong orientation of squirrel and damper cage models, see ticket#1226;this also includes the removal of the rotor cage heat sensor which previously has been used
- Bug fix of conditional initialization of examples, see ticket#1223
- Fixed missing default parameter TpmOperational in ambient of PM synchronous machine, see ticket#1216#1216
- Added voltages, currents, complex flux and magnetic potential difference as global variables inmulti phase converter
- Added two more component examples, showing the equivalent nature of electrical and magnetic domain
Version 2.0.0, 2013-03-10
- Corrected wrong parameter descriptions, see ticket#1003
- Extended machine models towards phase numbers to greater or equal than three, see ticket#990
Version 1.7.3, 2013-02-25
- Corrected wrong parameter description
Version 1.7.2, 2011-06-28
- Corrected bug in calculation of core conductance inSymmetricMultiPhaseWinding:the wrong calculation
G=(m/2)*GcRef/effectiveTurns^2
is now replaced byG=(m/2)*GcRef*effectiveTurns^2
Version 1.7.1, 2010-09-03
- Naming and documentation ofPartialTwoPort is exchanged byPartialTwoPortElementary to match the naming conventions ofRotational.Interfacesand Translational.Interfaces
- Fixed a broken link and updated documentation
- Adaptions to Complex SIunits
Version 1.7.0, 2010-05-31
- Changed symmetric multi phase winding model
- Added zero sequence inductance based on zero inductor
- Replaced electrical model of stray inductor by stray reluctance model
- Integrated cores losses and heat port
- Added rotor core loss parameters in asynchronous induction machine with slip rings
- Renamed heat ports of single phase winding and symmetric multi phase winding
- Relocated core losses between zero inductor and stray reluctance model in the magnetic domain
- Renamed instances of stator and rotor (winding) models in each machines
- Added magnetic potential sensor
- Removed state selections
- Updates due to changed loss variable and heat port names in Electrical.Machines
- Added machine specific output records to summarize power and loss balance
- Updated images of Users Guide
- Improved performance due to
annotation(Evaluate=true)
added to the parameters of the single phase winding - Reduced number of states in symmetric cage model by introducing an additional non-grounded star connection
Version 1.6.0, 2010-05-05
- Renamed all parameters
windingAngle
toorientation
. The following classes are affected: - Update due to changed class names in Machines.Icons
- Using HeatTransfer.Interfaces.PartialElementaryConditionalHeatPort instead of Analog.Interfaces.ConditionalHeatPort in EddyCurrent
- Added
modelica://
to all Modelica hyper links - Fixed bug in displayed parameters of EddyCurrent
- Updated some images (and renamed image file
LossPower.png
tolossPower.png
) - Exchanged positive and negative stator ports of RotorSaliencyAirGapmodel, adapted equations accordingly and updated code documentation.
Version 1.5.0, 2010-04-28
- Added stator core, friction, stray load and brush losses to all machine types based onloss models of the Machines library.
- Changed parameter ofEddyCurrentmodel from R to G
- Fixed wrong sign of internal quantity
tauElectrical
, model behavior does not change - Rewrote equations of electromagnetic coupling to look more elegant
Version 1.4.0, 2010-04-22
- Added eddy current model in accordance to FluxTubes library
- Added thermal heat port to eddy current model
- Minor updates due to dependencies of Machines
Version 1.3.0, 2010-02-26
- Changed some icon references
- Added state selections for the machine models
- Restructured partial machine model
- Added copyright information
Version 1.2.0, 2010-02-17
- Renamed Machines to BasicMachines
- Updated dependencies due to renamed classLinearTemperatureCoefficient20
- Added release notes in User's Guide
Version 1.1.0, 2010-02-15
- Added thermal connectors and temperature dependent resistances
Version 1.0.0, 2010-02-04
- Integrated the library into the MSL
Version 0.4.0, 2009-10-29
- Corrected bug in magnetic potential calculation
Version 0.3.0, 2009-10-28
- Renamed number of turns and winding angles
Version 0.2.0, 2009-10-20
- Added idle model
Version 0.1.0, 2009-07-22
- First version based on the concept of the FluxTubes library and the Magnetics library of Michael Beuschel[Beuschel00]