Edit Temperature Factor
Select a temperature factor and define its properties.
The temperature factor icon is enabled when performing SN (uniaxial, multiaxial) and EN (uniaxial, multiaxial) fatigue analysis.
-
Click the Material tool.
The Assign Material dialog opens.
- Under the Temperature Factor field heading, click .
-
In the dialog, select temperature factor from the drop-down menu.
- None: Ctemp = 1
- User Defined: Enter a Ctemp value between 0.0 and 1.0
- FKm: Input a temperature in degrees Celsius and select a material type. Ctemp is automatically calculated.
-
Click OK.
The temperature factor is used to update the fatigue strength reduction factor.
Kf (mod) = Kf / Ctemp
Tip: Apply a temperature factor value to all the parts/sets by
right-clicking on and
selecting Apply current value to all Parts/Sets.