ConstantMagneticPotentialDifference
Constant magnetomotive force
Library
Modelica/Magnetic/FluxTubes/Sources
Description
Magnetic circuits under steady-state conditions, i.e., with stationary magnetic fields (change of magnetic flux dΦ/dt = 0) can be described with constant sources of a magnetic potential difference or magnetomotive force (mmf). Constant magnetic potential differences are imposed by
- coils with stationary current (di / dt = 0) and
- permanent magnets modelled with Thévenin's equivalent magnetic circuit.
For modelling of reluctance actuators with this source component it is assumed that the armature is fixed so that no motion-induced flux change dΦ/dt can occur.
Parameters
Name | Label | Description | Data Type | Valid Values |
---|---|---|---|---|
mo_V_m | V_m | Magnetic potential difference | Scalar |
Name | Label | Description | Data Type | Valid Values |
---|---|---|---|---|
mo__nmodifiers | Number of Modifiers | Specifies the number of modifiers | Number | |
mo__modifiers | Modifiers | Add new modifier | Structure | |
mo__modifiers/varname | Variable name | Cell of strings | 'Phi' | |
mo__modifiers/attribute | Attribute | Cell of strings | 'start' | |
mo__modifiers/value | Value |
Ports
Name | Type | Description | IO Type | Number |
---|---|---|---|---|
port_p | implicit | Positive magnetic port | input | 1 |
port_n | implicit | Negative magnetic port | output | 1 |