OpenTank

    OpenTank

Library

HydraulicsByFluidon/Components/Volumes

Description

The OpenTank component is the model of an open tank with unlimited volume in the sense of a line termination. The pressure at fluidPort can either be set to environment.pAmbient pressure or a different pressure.

Parameters

OpenTank_0

NameLabelDescriptionData TypeValid Values

mo_useEnvironmentPressure

useEnvironmentPressure

Pressure at the fluid port equals environment.pAmbient

Scalar

true
false

mo_pressure

pressure

Pressure at the fluid port if useAmbientPressure = false

Scalar

OpenTank_1

NameLabelDescriptionData TypeValid Values

mo__nmodifiers

Number of Modifiers

Specifies the number of modifiers

Number

mo__modifiers

Modifiers

Add new modifier

Structure

mo__modifiers/varname

Variable name

Cell of strings

mo__modifiers/attribute

Attribute

Cell of strings

'start'
'fixed'

mo__modifiers/value

Value

Ports

NameTypeDescriptionIO TypeNumber

fluidPort

implicit

Hydraulic port

input

1