ValveEdgeTableQpx

    ValveEdgeTableQpx

Library

HydraulicsByFluidon/Components/Valves/Base

Description

The component ValveEdgeTableQpx is a model of an adjustable flow resistance which is parameterized through a look-up table of the flow rate.

The look-up table provides the flow rate as a function of acting pressure difference (difference between pressures ports A and B) and Input signal. Information regarding the formatting of the look-up table can be found in the documentation of the component ResistorTableQpx. Unlike the Resistor component, the look-up table for valveEdgeTableQpx is declared for the input range from -1 to 1.

Parameters

ValveEdgeTableQpx_0

NameLabelDescriptionData TypeValid Values

mo_fileName

fileName

File where look-up table is stored

String

mo_tableName

tableName

Table name on file

String

mo_ReferenceDensity

ReferenceDensity

Reference density

Scalar

mo_inputMin

inputMin

Minimum value of the input for look-up table

Scalar

ValveEdgeTableQpx_1

NameLabelDescriptionData TypeValid Values

mo_forwardFluidProperties

forwardFluidProperties

Forward fluid properties between ports

Scalar

true
false

ValveEdgeTableQpx_2

NameLabelDescriptionData TypeValid Values

mo__nmodifiers

Number of Modifiers

Specifies the number of modifiers

Number

mo__modifiers

Modifiers

Add new modifier

Structure

mo__modifiers/varname

Variable name

Cell of strings

'dp'
'volumeFlowA'
'volumeFlowB'

mo__modifiers/attribute

Attribute

Cell of strings

'start'
'fixed'

mo__modifiers/value

Value

Ports

NameTypeDescriptionIO TypeNumber

Input

implicit

input

1

Offset

implicit

input

2

InputMax

implicit

input

3

portA

implicit

input

4

portB

implicit

input

5