VariableFlowSource
Library
HydraulicsByFluidon/Components/Sources
Description
The component VariableFlowSource provides a volume flow according to the input signal at Port volumeFlow. The resulting mass flow at fluidPort depends the calculated density.
Parameters
Name | Label | Description | Data Type | Valid Values |
---|---|---|---|---|
mo__nmodifiers | Number of Modifiers | Specifies the number of modifiers | Number | |
mo__modifiers | Modifiers | Add new modifier | Structure | |
mo__modifiers/varname | Variable name | Cell of strings | 'outVolumeFlow' | |
mo__modifiers/attribute | Attribute | Cell of strings | 'start' | |
mo__modifiers/value | Value |
Ports
Name | Type | Description | IO Type | Number |
---|---|---|---|---|
fluidPort | implicit | Hydraulic port | input | 1 |
volumeFlow | implicit | Flow Rate | input | 2 |