ResistorAlphaDA

    ResistorAlphaDA

Library

HydraulicsByFluidon/Components/Resistors

Description

The component ResistorAlphaDA is a model of a flow resistance that behaves like an orifice.

The flow rate is calculated according to the formula given below:

where is given by the input AlphaDA.

Parameters

ResistorAlphaDA_0

NameLabelDescriptionData TypeValid Values

mo_dp

dp

dp

Structure

mo_dp/fixed

fixed

Cell of scalars

true
false

mo_dp/start

start

Cell of scalars

mo_InputMax

InputMax

Scalar

ResistorAlphaDA_1

NameLabelDescriptionData TypeValid Values

mo_forwardFluidProperties

forwardFluidProperties

Forward fluid properties between ports

Scalar

true
false

ResistorAlphaDA_2

NameLabelDescriptionData TypeValid Values

mo__nmodifiers

Number of Modifiers

Specifies the number of modifiers

Number

mo__modifiers

Modifiers

Add new modifier

Structure

mo__modifiers/varname

Variable name

Cell of strings

'volumeFlowA'
'volumeFlowB'
'fluidId'

mo__modifiers/attribute

Attribute

Cell of strings

'start'
'fixed'

mo__modifiers/value

Value

Ports

NameTypeDescriptionIO TypeNumber

fluidPortA

implicit

Hydraulic port A

input

1

fluidPortB

implicit

Hydraulic port B

input

2

alphaDA

implicit

Input alphaD * A

input

3

See Also