AnnularGap
Annular Gap
Library
HydraulicsByFluidon/Components/Resistors
Description
The component AnnularOrifice is a model of a flow resistance of a fully-developed laminar flow in the gap of a circular tube with an insert. The insert can be located off-center from the tube by the Eccentricity ratio.
The Eccentricity ratio is defined by
Eccentricity ratio = eccentricity / min(Gap Height A, Gap Height B), 0 <= Eccentricity ratio <= 1
Parameters
Name | Label | Description | Data Type | Valid Values |
---|---|---|---|---|
mo_Diameter | Diameter | Outer diameter | Scalar | |
mo_GapHeightA | GapHeightA | Gap Height A | Scalar | |
mo_GapHeightB | GapHeightB | Gap Heigt B | Scalar | |
mo_Length | Length | Length | Scalar | |
mo_relEccentricity | relEccentricity | Eccentricity ratio | Scalar | |
mo_InputMax | InputMax | Scalar | ||
mo_dp | dp | dp | Structure | |
mo_dp/fixed | fixed | Cell of scalars | true | |
mo_dp/start | start | Cell of scalars |
Name | Label | Description | Data Type | Valid Values |
---|---|---|---|---|
mo_forwardFluidProperties | forwardFluidProperties | Forward fluid properties between ports | Scalar | true |
Name | Label | Description | Data Type | Valid Values |
---|---|---|---|---|
mo__nmodifiers | Number of Modifiers | Specifies the number of modifiers | Number | |
mo__modifiers | Modifiers | Add new modifier | Structure | |
mo__modifiers/varname | Variable name | Cell of strings | 'volumeFlowA' | |
mo__modifiers/attribute | Attribute | Cell of strings | 'start' | |
mo__modifiers/value | Value |
Ports
Name | Type | Description | IO Type | Number |
---|---|---|---|---|
fluidPortA | implicit | Hydraulic port A | input | 1 |
fluidPortB | implicit | Hydraulic port B | input | 2 |