ADAPTFEKO
View the list of messages that may be reported by ADAPTFEKO.
Errors
- Error 31000:
- Please specify the integer 'x' after the option '--restart'.
- Error 31001:
- An integer value larger than zero must follow the command line option '--restart'.
- Error 31002:
- Unknown command line option '<text>'.
- Error 31004:
- Error while writing data to the *.bof file.
- Error 31006:
- Error opening the file '<text>'.
- Error 31011:
- The minimum frequency must be greater than zero.
- Error 31012:
- The maximum frequency must be larger than the minimum frequency.
- Error 31013:
- The number of frequency points must be greater than two.
- Errors 31015, 31049, 31051, 31053, 31073:
- Error opening file <text>.
- Errors 31016, 31031:
- Error opening file <text> (rc=<number>).
- Error 31017:
- The number of data blocks in the current bof file differs from that of the previous analysis.
- Error 31018:
- The file <text> seems to be corrupt (no end block found).
- Error 31019:
- Block version <number> not understood by this version of ADAPTFEKO (impedance data block, id=<number>).
- Error 31020:
- Block version <number> not understood by this version of ADAPTFEKO (S-parameter block, id=<number>).
- Error 31021:
- Block version <number> not understood by this version of ADAPTFEKO (far field data block, id=<number>).
- Error 31022:
- Block version <number> not understood by this version of ADAPTFEKO (near field data block, id=<number>).
- Error 31023:
- Block version <number> not understood by this version of ADAPTFEKO (current and charges data block, id=<number>).
- Error 31024:
- Block version <number> not understood by this version of ADAPTFEKO (power data block, id=<number>).
- Error 31025:
- Block version <number> not understood by this version of ADAPTFEKO (non-radiating network data block, id=<number>) .
- Errors 31028, 31030, 31129:
- Error occurred while trying to read from the file <text>.
- Error 31032:
- Internal error in subroutine bof_write_coeff_farfield.
- Error 31042:
- The frequency in the bof file differs from the current frequency.
- Error 31043:
- Structure of the bof file is not allowed to change over frequency.
- Error 31045:
- Using more than one AC-card is not supported.
- Error 31046:
- The number of frequency sampling points for the CableMod/Touchstone export must be greater than zero.
- Error 31047:
- Wrong value of the parameter I4 in the FR-card (must be 0 or 1).
- Error 31052:
- The number of frequency points in the *.rsd file must be greater than one.
- Error 31054:
- For CableMod please use a current version of PREFEKO (FEK-format >= 53).
- Error 31055:
- It is not allowed to have an FR card and an AC card at the same time (adaptive frequency sampling).
- Error 31056:
- Internal error: Requested CC_DATA_VERSION=2 not available.
- Errors 31058, 31059:
- Error while reading the currents from the *.rsd file.
- Error 31060:
- Block version <number> not understood by this version of ADAPTFEKO (header data block, id=<number>).
- Errors 31061, 31074:
- ADAPTFEKO run will terminate now due to error in RUNFEKO.
- Error 31065:
- Error while reading data from the *.bof file (rc=<number>).
- Errors 31066, 31067:
- Error when closing the file <text> (rc=<number>).
- Errors 31003, 31033, 31034, 31035, 31036, 31037, 31041, 31057, 31069, 31070, 31071, 31075, 31076, 31082, 31128, 31130, 31136:
- Error allocating memory for adaptive frequency interpolation.
- Error 31081:
- No S-parameter data was found in the *.bof file.
- Error 31104:
- Block version <number> not understood by this version of ADAPTFEKO (planar trans/refl data block, id=<number>).
- Error 31106:
- Block version <number> not understood by this version of ADAPTFEKO (SPICE probe data block, id=<number>).
- Error 31109:
- Initialising file compression failed.
- Error 31110:
- File compression failed.
- Error 31111:
- Time detected to run backwards (Feko time output is possibly not usable).
- Error 31112:
- Block version <number> not understood by this version of ADAPTFEKO (characteristic mode data block, id=<number>).
- Error 31113:
- Internal error in subroutine bof_merge_ada_files.
- Error 31117:
- Internal error in subroutine bof_merge_fr_files.
- Error 31121:
- Continuous frequency results are not yet supported in connection with the Finite Difference Time Domain (FDTD) solver. Please use a discrete frequency stepping instead..
- Error 31122:
- Block version <number> not understood by this version of ADAPTFEKO (interp. far field data block, id=<number>).
- Error 31124:
- Internal error: Error interpolating a function with infinite values.
- Error 31126:
- Block version <number> not understood by this version of ADAPTFEKO (modal port data block, id=<number>).
- Errors 31131, 31132, 31133, 31134, 31135:
- Error calculating the adaptive frequency interpolation.
- Error 31138:
- ADAPTFEKO will be terminated after waiting 10 minutes for the cleanup process to complete.
- Errors 31142, 31144, :
- Error opening file <text> for reading.
- Errors 31014, 31026, 31027, 31040, 31064, 31072, 31077, 31080, 31141, 31143, :
- Error creating file <text>.
Warnings
- Warning 31005:
- ADAPTFEKO terminated: The maximum number of sample points was reached.
- Warning 31062:
- ADAPTFEKO: Frequency subinterval <number> of <number> has not converged.
- Warning 31068:
- ADAPTFEKO requires *.fek file format 92 or newer to specify the termination accuracy, therefore using default value.
- Warning 31083:
- No calculation requests were made for adaptive frequency sampling.
- Warning 31096:
- ADAPTFEKO has reached minimum frequency stepping, results might not have converged.
- Warning 31097:
- ADAPTFEKO has at least once reached the minimum frequency stepping and terminated prematurely (possibly no convergence).
- Warning 31102:
- ADAPTFEKO requires *.fek file format 118 or newer to specify the quantity selection, therefore using default value.
- Warning 31123:
- Characteristic mode results are not used for adaptive frequency sampling.
- Warning 31137:
- ADAPTFEKO error detected during the cleanup process.