ADAPTFEKO

View the list of messages that may be reported by ADAPTFEKO.

Errors

Error 31000:
Please specify the integer 'x' after the option '--restart'.
Error 31001:
An integer value larger than zero must follow the command line option '--restart'.
Error 31002:
Unknown command line option '<text>'.
Error 31004:
Error while writing data to the *.bof file.
Error 31006:
Error opening the file '<text>'.
Error 31011:
The minimum frequency must be greater than zero.
Error 31012:
The maximum frequency must be larger than the minimum frequency.
Error 31013:
The number of frequency points must be greater than two.
Errors 31015, 31049, 31051, 31053, 31073:
Error opening file <text>.
Errors 31016, 31031:
Error opening file <text> (rc=<number>).
Error 31017:
The number of data blocks in the current bof file differs from that of the previous analysis.
Error 31018:
The file <text> seems to be corrupt (no end block found).
Error 31019:
Block version <number> not understood by this version of ADAPTFEKO (impedance data block, id=<number>).
Error 31020:
Block version <number> not understood by this version of ADAPTFEKO (S-parameter block, id=<number>).
Error 31021:
Block version <number> not understood by this version of ADAPTFEKO (far field data block, id=<number>).
Error 31022:
Block version <number> not understood by this version of ADAPTFEKO (near field data block, id=<number>).
Error 31023:
Block version <number> not understood by this version of ADAPTFEKO (current and charges data block, id=<number>).
Error 31024:
Block version <number> not understood by this version of ADAPTFEKO (power data block, id=<number>).
Error 31025:
Block version <number> not understood by this version of ADAPTFEKO (non-radiating network data block, id=<number>) .
Errors 31028, 31030, 31129:
Error occurred while trying to read from the file <text>.
Error 31032:
Internal error in subroutine bof_write_coeff_farfield.
Error 31042:
The frequency in the bof file differs from the current frequency.
Error 31043:
Structure of the bof file is not allowed to change over frequency.
Error 31045:
Using more than one AC-card is not supported.
Error 31046:
The number of frequency sampling points for the CableMod/Touchstone export must be greater than zero.
Error 31047:
Wrong value of the parameter I4 in the FR-card (must be 0 or 1).
Error 31052:
The number of frequency points in the *.rsd file must be greater than one.
Error 31054:
For CableMod please use a current version of PREFEKO (FEK-format >= 53).
Error 31055:
It is not allowed to have an FR card and an AC card at the same time (adaptive frequency sampling).
Error 31056:
Internal error: Requested CC_DATA_VERSION=2 not available.
Errors 31058, 31059:
Error while reading the currents from the *.rsd file.
Error 31060:
Block version <number> not understood by this version of ADAPTFEKO (header data block, id=<number>).
Errors 31061, 31074:
ADAPTFEKO run will terminate now due to error in RUNFEKO.
Error 31065:
Error while reading data from the *.bof file (rc=<number>).
Errors 31066, 31067:
Error when closing the file <text> (rc=<number>).
Errors 31003, 31033, 31034, 31035, 31036, 31037, 31041, 31057, 31069, 31070, 31071, 31075, 31076, 31082, 31128, 31130, 31136:
Error allocating memory for adaptive frequency interpolation.
Error 31081:
No S-parameter data was found in the *.bof file.
Error 31104:
Block version <number> not understood by this version of ADAPTFEKO (planar trans/refl data block, id=<number>).
Error 31106:
Block version <number> not understood by this version of ADAPTFEKO (SPICE probe data block, id=<number>).
Error 31109:
Initialising file compression failed.
Error 31110:
File compression failed.
Error 31111:
Time detected to run backwards (Feko time output is possibly not usable).
Error 31112:
Block version <number> not understood by this version of ADAPTFEKO (characteristic mode data block, id=<number>).
Error 31113:
Internal error in subroutine bof_merge_ada_files.
Error 31117:
Internal error in subroutine bof_merge_fr_files.
Error 31121:
Continuous frequency results are not yet supported in connection with the Finite Difference Time Domain (FDTD) solver. Please use a discrete frequency stepping instead..
Error 31122:
Block version <number> not understood by this version of ADAPTFEKO (interp. far field data block, id=<number>).
Error 31124:
Internal error: Error interpolating a function with infinite values.
Error 31126:
Block version <number> not understood by this version of ADAPTFEKO (modal port data block, id=<number>).
Errors 31131, 31132, 31133, 31134, 31135:
Error calculating the adaptive frequency interpolation.
Error 31138:
ADAPTFEKO will be terminated after waiting 10 minutes for the cleanup process to complete.
Errors 31142, 31144, :
Error opening file <text> for reading.
Errors 31014, 31026, 31027, 31040, 31064, 31072, 31077, 31080, 31141, 31143, :
Error creating file <text>.

Warnings

Warning 31005:
ADAPTFEKO terminated: The maximum number of sample points was reached.
Warning 31062:
ADAPTFEKO: Frequency subinterval <number> of <number> has not converged.
Warning 31068:
ADAPTFEKO requires *.fek file format 92 or newer to specify the termination accuracy, therefore using default value.
Warning 31083:
No calculation requests were made for adaptive frequency sampling.
Warning 31096:
ADAPTFEKO has reached minimum frequency stepping, results might not have converged.
Warning 31097:
ADAPTFEKO has at least once reached the minimum frequency stepping and terminated prematurely (possibly no convergence).
Warning 31102:
ADAPTFEKO requires *.fek file format 118 or newer to specify the quantity selection, therefore using default value.
Warning 31123:
Characteristic mode results are not used for adaptive frequency sampling.
Warning 31137:
ADAPTFEKO error detected during the cleanup process.