Slot thermal model - Inputs
Slot thermal model - Inputs
The thermal exchanges from the conductors to the stator core are complex phenomena for which a dedicated model is embedded.
This panel allows choosing the conduction model from the conductors to the stator core.
By default, a FluxMotor model is proposed. This model uses the slot fill factor, the conductor shape, and the conductivities of the materials inside the slot, to compute two equivalent conductivities:
- The radial and orthoradial conductivity of the winding, used to compute thermal exchanges from the winding to the stator core.
- The axial conductivity of the winding used to compute thermal exchanges from the in-slot winding to the end windings.
|
|
Internal cooling – slot model design area | |
1 | Display the axial and radial view of the machine. |
2 | Display the internal cooling datasheet, showing the thermal parameters defining the internal heat exchanges. |
3 | Radial view of the motor, where specific exchange areas can be highlighted depending on the selected input. |
4 | Axial view of the motor, where specific exchange areas can be highlighted depending on the selected input. |
5 | The section “Slot model” is selected. |
6 | Button to set the slot conductivities automatically by internal process. |
7 | Selected button, to set the user slot conductivities. |
8 | Equivalent conductivities, to be set only when the User mode has been
chosen. In user mode, the following inputs must be set:·
|
9 | Button to restore default input values. |
10 | Button to apply inputs. Pressing the enter key twice applies inputs too. |
11 | Icon to export internal cooling data into *.txt or *.xlsx files. |