Working point - U-f-N - Transient application
Positioning and objective
The aim of the test “Working point – Sine wave – Motor – U, f, N” is to characterize the behavior of the machine when operating at the targeted input values U, f, N (Line-line voltage, power supply frequency and speed).
The resulting model is fully parameterized, and it is built in Altair® Flux® 2D environment, transient application.
The results of this test give an overview of the electromagnetic analysis of the machine considering its topology.
It also gives the capability to make comparisons between results obtained from measurements with Altair® FluxMotor® .
The following section describes all the user inputs to initialize the exported model.
All these parameters can be modified in Flux® 2D environment if needed.