Inputs
1. Standard inputs
-
Line-line voltage, rms
The line-line voltage supplied to the machine: “Line-line voltage, rms” ( Line-line voltage, rms value ) must be provided.
-
Slip or Speed mode
There are two usual parameters to define the working point. It can be defined by the slip “ Slip ” or by the mechanical speed “ Speed ”.
-
Slip
If the “Definition mode” is “ Slip ”, the value of the machine’s slip must be provided, and the corresponding speed is deduced.
The slip “s” in the following relations) corresponds to the relative difference between the synchronous speed (N Synch. ) and rotor speed N:
-
Speed
If the “Definition mode” is “ Speed ”, the targeted rotor speed must be provided, and the resulting slip is deduced.
-
Power supply frequency
The power supply frequency corresponds to the electrical frequency of the stator magnetic field.
2. Advanced inputs
The lists of advanced inputs dedicated to this export are listed below.
For more details please refer to the list of generic advanced inputs.
- Rotor initial position
-
Mesh order
The default level is second order mesh.
-
Airgap mesh coefficient
Airgap mesh coefficient is set to 1.5 by default.