Package Modelica.​Electrical.​PowerConverters.​Examples.​ACDC.​RectifierCenterTap2mPulse
2*m pulse rectifier with center tap

Information

This package includes multi phase center tap rectifiers. The number of phases, m, determines the number of pulses, 2*m. The examples show uncontrolled and controlled rectifiers with constant and variable firing angle.

Extends from Modelica.​Icons.​ExamplesPackage (Icon for packages containing runnable examples).

Package Contents

NameDescription
DiodeCenterTap2mPulse2*m pulse diode center tap rectifier with resistive load
ThyristorCenterTap2mPulse_R2*m pulse thyristor center tap rectifier with resistive load
ThyristorCenterTap2mPulse_RL2*m pulse thyristor rectifier with R-L load
ThyristorCenterTap2mPulse_RLV2*m pulse thyristor center tap rectifier with R-L load and voltage
ThyristorCenterTap2mPulse_RLV_CharacteristicCharacteristic of 2*m pulse center tap thyristor rectifier with R-L load and voltage

Model Modelica.​Electrical.​PowerConverters.​Examples.​ACDC.​RectifierCenterTap2mPulse.​DiodeCenterTap2mPulse
2*m pulse diode center tap rectifier with resistive load

Information

This example shows an uncontrolled 2*m pulse center tap diode rectifier with resistive load, where m is the number of phases.

Plot current currentSensor.i, average current meanCurrent.y, voltage voltageSensor.v and average voltage meanVoltage.v.

Extends from Modelica.​Icons.​Example (Icon for runnable examples).

Parameters

TypeNameDefaultDescription
Integerm3Number of phases
VoltageVrms110RMS supply voltage
Frequencyf50Frequency
ResistanceR20Load resistance

Model Modelica.​Electrical.​PowerConverters.​Examples.​ACDC.​RectifierCenterTap2mPulse.​ThyristorCenterTap2mPulse_R
2*m pulse thyristor center tap rectifier with resistive load

Information

This example shows a controlled 2*m pulse center tap rectifier with resistive load, where m is the number of phases.

Plot current currentSensor.i, average current meanCurrent.y, voltage voltageSensor.v and average voltage meanVoltage.v.

Extends from Modelica.​Electrical.​PowerConverters.​Examples.​ACDC.​ExampleTemplates.​ThyristorCenterTap2mPulse (Template of 2*m pulse thyristor rectifier with center tap) and Modelica.​Icons.​Example (Icon for runnable examples).

Parameters

TypeNameDefaultDescription
Integerm3Number of phases
VoltageVrms110RMS supply voltage
Frequencyf50Frequency
AngleconstantFiringAngle0.005555555555556 * (30 * pi)Firing angle
ResistanceR20Load resistance

Model Modelica.​Electrical.​PowerConverters.​Examples.​ACDC.​RectifierCenterTap2mPulse.​ThyristorCenterTap2mPulse_RL
2*m pulse thyristor rectifier with R-L load

Information

This example shows a controlled 2*m pulse center tap rectifier with R-L load, where m is the number of phases.

Plot current currentSensor.i, average current meanCurrent.y, voltage voltageSensor.v and average voltage meanVoltage.v.

Extends from Modelica.​Electrical.​PowerConverters.​Examples.​ACDC.​ExampleTemplates.​ThyristorCenterTap2mPulse (Template of 2*m pulse thyristor rectifier with center tap) and Modelica.​Icons.​Example (Icon for runnable examples).

Parameters

TypeNameDefaultDescription
Integerm3Number of phases
VoltageVrms110RMS supply voltage
Frequencyf50Frequency
AngleconstantFiringAngle0.005555555555556 * (30 * pi)Firing angle
ResistanceR20Load resistance
InductanceL1Load resistance

Model Modelica.​Electrical.​PowerConverters.​Examples.​ACDC.​RectifierCenterTap2mPulse.​ThyristorCenterTap2mPulse_RLV
2*m pulse thyristor center tap rectifier with R-L load and voltage

Information

This example shows a controlled 2*m pulse center tap rectifier with R-L load including DC voltage source, where m is the number of phases. The additional DC voltage source in this example enables negative average load voltages.

Plot current currentSensor.i, average current meanCurrent.y, voltage voltageSensor.v and average voltage meanVoltage.v.

Extends from Modelica.​Electrical.​PowerConverters.​Examples.​ACDC.​ExampleTemplates.​ThyristorCenterTap2mPulse (Template of 2*m pulse thyristor rectifier with center tap) and Modelica.​Icons.​Example (Icon for runnable examples).

Parameters

TypeNameDefaultDescription
Integerm3Number of phases
VoltageVrms110RMS supply voltage
Frequencyf50Frequency
AngleconstantFiringAngle0.005555555555556 * (30 * pi)Firing angle
ResistanceR20Load resistance
InductanceL1Load resistance
VoltageVDC-260DC load offset voltage

Model Modelica.​Electrical.​PowerConverters.​Examples.​ACDC.​RectifierCenterTap2mPulse.​ThyristorCenterTap2mPulse_RLV_Characteristic
Characteristic of 2*m pulse center tap thyristor rectifier with R-L load and voltage

Information

This example shows a controlled 2*m pulse center tap rectifier with R-L load including DC voltage source, where m is the number of phases. The additional DC voltage source in this example enables negative average load voltages.

Plot average voltage meanVoltage.v versus firingAngle pulsem.firingAngle to see control characteristic of this type of rectifier with R-L load including active voltage.

Extends from Modelica.​Electrical.​PowerConverters.​Examples.​ACDC.​ExampleTemplates.​ThyristorCenterTap2mPulse (Template of 2*m pulse thyristor rectifier with center tap) and Modelica.​Icons.​Example (Icon for runnable examples).

Parameters

TypeNameDefaultDescription
Integerm3Number of phases
VoltageVrms110RMS supply voltage
Frequencyf50Frequency
ResistanceR20Load resistance
InductanceL1Load resistance
VoltageVDC-260DC load offset voltage