Example 3: Radiation Map Simulation with Frequency Sweep

This case explains how to calculate far-field, radiation pattern, current density, charge density, and radiation map of an open box with a dipole antenna insides the box and a frequency sweep from 0.5 GHz to 1.5 GHz with 3 examples.

Step 1: Create a new MOM Project.

Open newFASANT and select 'File --> New' option.

Figure 1. New Project panel


Select 'MOM' option on the previous figure and start to configure the project.

Step 2: Create the geometry model. To obtain more information about geometries generation see Parameters.

Execute 'box' command writing it on the command line and sets the parameters as the next figure shows when command line ask for it.

Figure 2. Box parameters


Select box geometry on the main panel and execute 'explode' command writing it on the command line. Then the box will be transformed into 6 surfaces.

Figure 3. Box selection and 'explode' command


Select the top surface and execute 'delete' command. Then the surface will be removed from the geometry.

Figure 4. Surface selection and 'delete' command


Select all remaining surfaces and execute 'group' command.

Figure 5. Surfaces selection and 'group' command


Step 3: Set Simulation Parameters

Select 'Simulation --> Parameters' option on the menu bar and the following panel appears. Set the parameters as the next figure shows and save it.

Figure 6. Simulation Parameters panel


Step 4: Set the source parameters. To obtain more information about sources and antennas see Antennas.

Select 'Source --> Dipole --> Dipole Antenna' option and set the parameters as show the next figure. Then save the parameters and the dipole appears.

Figure 7. Dipole Antenna panel


Step 5: Meshing the geometry model.

Select 'Meshing --> Parameters' to open the meshing configuration panel and then set the parameters as show the next figure. In order to obtain the shortest possible time for meshing,it is recommended to run the process of meshing with the number of physical processors available to the machine.

Figure 8. Meshing panel


Then click on 'Mesh' button to starting the meshing. A panel appears to display meshing process information.

Figure 9. Meshing process log


Step 6: Execute the simulation. In order to obtain the shortest possible time for calculating the results,it is recommended to run the process with the number of physical processors available to the machine.

Select 'Calculate --> Execute' option to open simulation parameters. Then select the number of processors as the next figure show.

Figure 10. Execute panel


Then click on 'Execute' button to starting the simulation. A panel appears to display execute process information.

Figure 11. Execute process log


Step 7: Show Results. To get more information about the graphics panel advanced options (clicking on right button of the mouse over the panel) see Annex 1: Graphics Advanced Options.

Select 'Show Results --> Far Field --> View Cuts' option to show the cuts of the observation directions options.

Figure 12. Far Field cuts


Selecting other values for the component, step, frequency or cut parameters and clicking on 'Add Series' button a new cut will be added to the selected parameters. On 'Show Results --> Far Field' menu, other results are present such as 'View Cuts by Step' and 'View Cuts by Frequency' and this option display the values for one selected point for each step or frequency.

Figure 13. Far Field by Frequency cuts


Select 'Show Results --> Radiation Pattern --> View Cuts' option to show the cuts of the radiation pattern options.

Figure 14. Radiation Pattern cuts


Selecting other values for the component, step, frequency or cut parameters and clicking on 'Add Series' button a new cut will be added to the selected parameters. On 'Show Results --> Radiation Pattern' menu, other results are present such as 'View Cuts by Step' and 'View Cuts by Frequency' and this option display the values for one selected point for each step or frequency.

Select 'Show Results --> Radiation Pattern --> View 3D Pattern' option to show the cuts of the radiation pattern options.

Figure 15. Radiation Pattern 3D for frequency 0.5 GHz


Figure 16. Radiation Pattern 3D for frequency 1.0 GHz


Figure 17. Radiation Pattern 3D for frequency 1.5 GHz


Changing values for step, frequency, component or filtering parameters the visualization for the new parameters will be shown.

Select 'Show Results --> View Currents' option to show the current density.

Figure 18. Current Density for frequency 0.5 GHz


Changing values for step, frequency, magnitude, component or filtering parameters the visualization for the new parameters will be shown.

Figure 19. Current Density for frequency 1.5 GHz


Select 'Show Results --> View Charges' option to show the charge density.

Figure 20. Charge Density for frequency 0.5 GHz


Changing values for step, frequency, magnitude or filtering parameters the visualization for the new parameters will be shown.

Figure 21. Charge Density for frequency 1.5 GHz


Select 'Show Results --> View Radiation Map' option to show the radiation map.

Figure 22. Radiation Map for frequency 0.5 GHz


Changing values for step, frequency, magnitude, component or filtering parameters the visualization for the new parameters will be shown.

Figure 23. Radiation Map for frequency 1.5 GHz