Torque

Input signal acting as external torque on a flange

    Torque

Library

Modelica/Mechanics/Rotational/Sources

Description

The input signal tau defines an externaltorque in [Nm] which acts (with negative sign) ata flange connector, i.e., the component connected to thisflange is driven by torque tau.

The input signal can be provided from one of the signal generatorblocks of Modelica.Blocks.Sources.

Parameters

Torque_0

NameLabelDescriptionData TypeValid Values

mo_useSupport

useSupport

= true, if support flange enabled, otherwise implicitly grounded

Number

0
1

Torque_1

NameLabelDescriptionData TypeValid Values

mo__nmodifiers

Number of Modifiers

Specifies the number of modifiers

Number

mo__modifiers

Modifiers

Add new modifier

Structure

mo__modifiers/varname

Variable name

Cell of strings

'phi_support'

mo__modifiers/attribute

Attribute

Cell of strings

'start'
'fixed'

mo__modifiers/value

Value

Ports

NameTypeDescriptionIO TypeNumber

flange

implicit

Flange of shaft

output

1

tau

implicit

Accelerating torque acting at flange (= -flange.tau)

input

1

Port 3

implicit

Support/housing of component

input

mo_useSupport

See Also