Admittance

Single phase linear admittance

    Admittance

Library

Modelica/Electrical/QuasiStationary/SinglePhase/Basic

Description

The admittance model represents a parallel connection of a conductor and either a capacitor or inductor.

The linear admittance connects the voltage v with thecurrent i by i = Y*v. The resistivecomponent is modeled temperature dependent, so the real part G_actual = real(Y) is determined fromthe actual operating temperature and the reference input conductance real(Y_ref).A conditional heat port is considered.The reactive component B_actual = imag(Y)is equal to imag(Y_ref) if frequencyDependent = false.Frequency dependency is considered by frequencyDependent = true, distinguishing two cases:

(a) imag(Y_ref) > 0: capacitive case
The actual susceptance B_actual is proportional to f/f_ref
(b) imag(Y_ref) < 0: inductive case
The actual susceptance B_actual is proportional to f_ref/f

See also

Resistor,Conductor,Capacitor,Impedance,Variable resistor,Variable conductor,Variable capacitor,Variable inductor,Variable impedance,Variable admittance

Parameters

Admittance_0

NameLabelDescriptionData TypeValid Values

mo_T_heatPort

T_heatPort

T_heatPort

Structure

mo_T_heatPort/fixed

fixed

Cell of scalars

true
false

mo_T_heatPort/start

start

Cell of scalars

mo_Y_ref

Y_ref

Complex admittance G_ref + j*B_ref

mo_T_ref

T_ref

Reference temperature

Scalar

mo_alpha_ref

alpha_ref

Temperature coefficient of resistance (R_actual = R_ref*(1 + alpha_ref*(heatPort.T - T_ref))

Scalar

mo_useHeatPort

useHeatPort

=true, if heatPort is enabled

Number

0
1

mo_T

T

Fixed device temperature if useHeatPort = false

Scalar

mo_frequencyDependent

frequencyDependent

Consider frequency dependency, if true

Scalar

true
false

mo_f_ref

f_ref

Reference frequency, if frequency dependency is considered

Scalar

mo_G_ref

G_ref

Resistive component of conductance

Scalar

mo_B_ref

B_ref

Reactive component of susceptance

Scalar

Admittance_1

NameLabelDescriptionData TypeValid Values

mo__nmodifiers

Number of Modifiers

Specifies the number of modifiers

Number

mo__modifiers

Modifiers

Add new modifier

Structure

mo__modifiers/varname

Variable name

Cell of strings

'abs_v'
'arg_v'
'abs_i'
'arg_i'
'P'
'Q'
'S'
'pf'
'omega'
'LossPower'
'G_actual'
'B_actual'

mo__modifiers/attribute

Attribute

Cell of strings

'start'
'fixed'

mo__modifiers/value

Value

Ports

NameTypeDescriptionIO TypeNumber

pin_p

implicit

Positive quasi-static single-phase pin

input

1

pin_n

implicit

Negative quasi-static single-phase pin

output

1

Port 3

implicit

Conditional heat port

input

mo_useHeatPort