VariableConductor

Ideal linear electrical conductors with variable conductance

    VariableConductor

Library

Modelica/Electrical/MultiPhase/Basic

Description

Contains m variable conductors (Modelica.Electrical.Analog.Basic.VariableConductor)

Attention!!!
It is recommended that none of the G_Port signals should not cross the zero value. Otherwise depending on the surrounding circuit the probability of singularities is high.

Parameters

VariableConductor_0

NameLabelDescriptionData TypeValid Values

mo_m

m

Number of phases

Scalar

mo_T_ref

T_ref

Reference temperatures

Vector

mo_alpha

alpha

Temperature coefficients of conductances at reference temperatures

Vector

mo_mh

mh

Number of heatPorts=number of phases

Scalar

mo_useHeatPort

useHeatPort

=true, if all heat ports are enabled

Number

0
1

mo_T

T

Fixed device temperatures if useHeatPort = false

Vector

VariableConductor_1

NameLabelDescriptionData TypeValid Values

mo__nmodifiers

Number of Modifiers

Specifies the number of modifiers

Number

mo__modifiers

Modifiers

Add new modifier

Structure

mo__modifiers/varname

Variable name

Cell of strings

'v'
'i'

mo__modifiers/attribute

Attribute

Cell of strings

'start'
'fixed'

mo__modifiers/value

Value

Ports

NameTypeDescriptionIO TypeNumber

plug_p

implicit

Positive polyphase electrical plug with m pins

input

1

plug_n

implicit

Negative polyphase electrical plug with m pins

output

1

G

implicit

input

2

Port 4

implicit

Conditional heat ports

input

mo_useHeatPort