SM_ReluctanceRotorData

Common parameters for synchronous induction machines with reluctance rotor

    SM_ReluctanceRotorData

Library

Modelica/Electrical/Machines/Utilities/ParameterRecords

Description

Basic parameters of synchronous induction machines with reluctance rotor are predefined with default values.

Parameters

SM_ReluctanceRotorData_0

NameLabelDescriptionData TypeValid Values

mo_m

m

Number of phases

Scalar

mo_Jr

Jr

Rotor's moment of inertia

Scalar

mo_Js

Js

Stator's moment of inertia

Scalar

mo_p

p

Number of pole pairs (Integer)

Scalar

mo_fsNominal

fsNominal

Nominal frequency

Scalar

mo_effectiveStatorTurns

effectiveStatorTurns

Effective number of stator turns

Scalar

SM_ReluctanceRotorData_1

NameLabelDescriptionData TypeValid Values

mo_Rs

Rs

Stator resistance per phase at TRef

Scalar

mo_TsRef

TsRef

Reference temperature of stator resistance

Scalar

mo_alpha20s

alpha20s

Temperature coefficient of stator resistance at 20 degC

Scalar

mo_Lszero

Lszero

Stator zero sequence inductance

Scalar

mo_Lssigma

Lssigma

Stator stray inductance per phase

Scalar

mo_Lmd

Lmd

Stator main field inductance per phase in d-axis

Scalar

mo_Lmq

Lmq

Stator main field inductance per phase in q-axis

Scalar

mo_useDamperCage

useDamperCage

Enable / disable damper cage

Scalar

true
false

mo_Lrsigmad

Lrsigmad

Damper stray inductance in d-axis

Scalar

mo_Lrsigmaq

Lrsigmaq

Damper stray inductance in q-axis

Scalar

mo_Rrd

Rrd

Damper resistance in d-axis at TRef

Scalar

mo_Rrq

Rrq

Damper resistance in q-axis at TRef

Scalar

mo_TrRef

TrRef

Reference temperature of damper resistances in d- and q-axis

Scalar

mo_alpha20r

alpha20r

Temperature coefficient of damper resistances in d- and q-axis

Scalar

SM_ReluctanceRotorData_2

NameLabelDescriptionData TypeValid Values

mo_frictionParameters

frictionParameters

Friction loss parameter record

FromModelica('Modelica.Electrical.Machines.Losses.FrictionParameters')

mo_statorCoreParameters

statorCoreParameters

Stator core loss parameter record; all parameters refer to stator side

FromModelica('Modelica.Electrical.Machines.Losses.CoreParameters')

mo_strayLoadParameters

strayLoadParameters

Stray load losses

FromModelica('Modelica.Electrical.Machines.Losses.StrayLoadParameters')

SM_ReluctanceRotorData_3

NameLabelDescriptionData TypeValid Values

mo__nmodifiers

Number of Modifiers

Specifies the number of modifiers

Number

mo__modifiers

Modifiers

Add new modifier

Structure

mo__modifiers/varname

Variable name

Cell of strings

mo__modifiers/attribute

Attribute

Cell of strings

'start'
'fixed'

mo__modifiers/value

Value