ThermalAmbientSMR
Thermal ambient for synchronous induction machine with reluctance rotor
Library
Modelica/Electrical/Machines/Thermal/SynchronousInductionMachines
Description
Thermal ambient for synchronous induction machines with reluctance rotor to prescribe winding temperatures either constant or via signal connectors.Additionally, all losses = heat flows are recorded.Parameters
Name | Label | Description | Data Type | Valid Values |
---|---|---|---|---|
mo_useDamperCage | useDamperCage | Enable / disable damper cage | Number | 0 |
mo_m | m | Number of stator phases | Scalar | |
mo_useTemperatureInputs | useTemperatureInputs | If true, temperature inputs are used; else, temperatures are constant | Number | 0 |
mo_Ts | Ts | Temperature of stator windings | Scalar | |
mo_Tr | Tr | Temperature of damper cage (optional) | Scalar |
Name | Label | Description | Data Type | Valid Values |
---|---|---|---|---|
mo__nmodifiers | Number of Modifiers | Specifies the number of modifiers | Number | |
mo__modifiers | Modifiers | Add new modifier | Structure | |
mo__modifiers/varname | Variable name | Cell of strings | 'Q_flowStatorWinding' | |
mo__modifiers/attribute | Attribute | Cell of strings | 'start' | |
mo__modifiers/value | Value |
Ports
Name | Type | Description | IO Type | Number |
---|---|---|---|---|
thermalPort | implicit | input | 1 | |
Port 2 | implicit | Temperature of stator windings | input | mo_useTemperatureInputs |
Port 3 | implicit | Temperature of damper cage (optional) | input | mo_useTemperatureInputs&&mo_useDamperCage |