Package Modelica.​Thermal.​HeatTransfer.​Fahrenheit
Components with Fahrenheit input and/or output

Information

The components of this package are provided for the convenience of people working mostly with Fahrenheit units, since all models in package HeatTransfer are based on Kelvin units.

Note, that in package SIunits.Conversions, functions are provided to convert between the units Kelvin, degree Celsius, degree Fahrenheit and degree Rankine. These functions allow, e.g., a direct conversion of units at all places where Kelvin is required as parameter. Example:

    import SIunits.Conversions.*;
    Modelica.Thermal.HeatTransfer.HeatCapacitor C(T0 = from_degF(70));

Extends from Modelica.​Icons.​VariantsPackage (Icon for package containing variants).

Package Contents

NameDescription
FixedTemperatureFixed temperature boundary condition in degFahrenheit
FromKelvinConversion from Kelvin to degFahrenheit
PrescribedTemperatureVariable temperature boundary condition in degFahrenheit
TemperatureSensorAbsolute temperature sensor in degFahrenheit
ToKelvinConversion block from degFahrenheit to Kelvin

Model Modelica.​Thermal.​HeatTransfer.​Fahrenheit.​ToKelvin
Conversion block from degFahrenheit to Kelvin

Information

This component converts a input signal from degree Fahrenheit to Kelvin and provides is as output signal.

Connectors

TypeNameDescription
input RealInputFahrenheit 
output RealOutputKelvin 

Model Modelica.​Thermal.​HeatTransfer.​Fahrenheit.​FromKelvin
Conversion from Kelvin to degFahrenheit

Information

This component converts all input signals from Kelvin to Fahrenheit and provides them as output signals.

Parameters

TypeNameDefaultDescription
Integern1Only kept for backwards compatibility (parameter is not used in the model and will be removed in a future version)

Connectors

TypeNameDescription
input RealInputKelvin 
output RealOutputFahrenheit 

Model Modelica.​Thermal.​HeatTransfer.​Fahrenheit.​FixedTemperature
Fixed temperature boundary condition in degFahrenheit

Information

This model defines a fixed temperature T at its port in [degF], i.e., it defines a fixed temperature as a boundary condition.

Parameters

TypeNameDefaultDescription
Temperature_degFT Fixed Temperature at the port

Connectors

TypeNameDescription
HeatPort_bport 

Model Modelica.​Thermal.​HeatTransfer.​Fahrenheit.​PrescribedTemperature
Variable temperature boundary condition in degFahrenheit

Information

This model represents a variable temperature boundary condition The temperature value in [degF] is given by the input signal to the model. The effect is that an instance of this model acts as an infinite reservoir able to absorb or generate as much energy as required to keep the temperature at the specified value.

Connectors

TypeNameDescription
HeatPort_bport 
input RealInputT 

Model Modelica.​Thermal.​HeatTransfer.​Fahrenheit.​TemperatureSensor
Absolute temperature sensor in degFahrenheit

Information

This is an ideal absolute temperature sensor which returns the temperature of the connected port in Fahrenheit as an output signal. The sensor itself has no thermal interaction with whatever it is connected to. Furthermore, no thermocouple-like lags are associated with this sensor model.

Connectors

TypeNameDescription
output RealOutputT 
HeatPort_aport