Supplied conductors application: post-processing quantities
Solving process: reminder
With the application Supplied conductors, the solving process requires two steps, as presented in the table below.
| PEEC computation (independent on the application) | 
|---|
| computation of resistances and partial self-inductances (R, L) of each
                        element of the conductor, computation of partial mutual inductances (M) among all the parallel elements of the conductor | 
| Computation of the current | 
|---|
| solving the electric equations ⇒ value of the current in each element | 
| Post-processing | 
|---|
| magnetic flux density, Joule losses, Laplace force,… | 
Local quantities
The local quantities issued from computation are presented in the table below.
| Quantity | Unit | Explanation | |
|---|---|---|---|
| Current density in conductors:   | complex vector | A/m2 | |
| Magnetic flux density:   | complex vector | T | Analytical (or semi- analytical): Biot and Savart | 
| Power losses density in conductors (by Joule effect): dP | real scalar | W/m3 |   | 
| Laplace force density:  average component | real vector | N/m3 |   | 
| Laplace force density:  pulsating component | complex vector | N/m3 | |
Global quantities
The global quantities issued from the computation are presented in the table below.
| Quantity | Unit | Explanation | |
|---|---|---|---|
| Total current carrying the conductor:   | complex scalar | A |   | 
| Power losses in the conductor (by Joule effect): P | real scalar | W |   | 
| Laplace Force on the conductor:  average component | real vector | N |   | 
| Laplace Force on the conductor:  pulsating component | complex vector | N | |