# Copyright (c) 2012-2024 by Altair Engineering, Inc.
# All rights reserved.
#
# Altair Engineering, Inc. makes this software available as part of the Vision
# tool platform.  As long as you are a licensee of the Vision tool platform
# you may make copies of the software and modify it to be used within the
# Vision tool platform, but you must include all of this notice on any copy.
# Redistribution without written permission to any third party, with or
# without modification, is not permitted.
# Altair Engineering, Inc. does not warrant that this software is error free
# or fit for any purpose.  Altair Engineering, Inc. disclaims any liability for
# all claims, expenses, losses, damages and costs any user may incur as a
# result of using, copying or modifying the software.
# =============================================================================
#   @script
#       Check for wrong bulk connections.
#
#       Algorithm
#           1. Identify all MOS devices in the design.
#           2. Check if the bulk pin of a PMOS device is connected to power.
#           3. Check if the bulk pin of a NMOS device is connected to ground.
#           4. Add the devices that violate the above rule to the result list.
#
#       Example
#           demo/api/erc/testcase03.sp
###############################################################################


# =============================================================================
# Check03 -
# =============================================================================
#
proc ERC:Check03 {db} {
    ##
    # Initialize the result list.
    #
    set resList {}

    ##
    # Flag devices in the loaded database.
    #
    zprogress push "" 0.05
    ERC:FlagDevices $db {"NMOS" "PMOS"}
    if {[zprogress pop]} {
        return
    }

    ##
    # Set expected net flags depending on the primitive function.
    #
    set _expected(NMOS) "ground"
    set _expected(PMOS) "power"

    ##
    # Loop over all modules in the loaded design.
    #
    zprogress push "" 1.0
    set mcount [$db count module]
    set m 0
    $db foreach module module {
        zmessage print DBG \
            "Process module [$db oid print $module]"

        zprogress push "" [expr {double([incr m]) / $mcount}]

        ##
        # Loop over all instances in the current module.
        #
        set icount [$db count inst $module]
        set i 0
        $db foreach inst $module inst {
            if {[zprogress update "" [incr i] $icount]} {
                break
            }

            ##
            # Skip all instances where the cell referenced by the instance
            # has the green flag not set.
            #
            if {![$db flag [$db down $inst] is green]} {
                continue
            }
            zmessage print DBG \
                "  Process instance [$db oid print $inst]"

            ##
            # Investigate only the bulk pin for wrong connections.
            #
            set bulkPin [$db getFuncPort $inst -name bulk]
            zmessage print DBG \
                "    Process bulk pin [$db oid print $bulkPin]"

            ##
            # Set the flag expected at the net connected to the bulk pin.
            #
            set flag $_expected([$db primFuncOf $inst])
            zmessage print DBG \
                "  Expect a '$flag' net at the bulk pin of this instance."

            ##
            # Check if the bulk pin is not connected to a power/ground node
            # identified by the given flag.
            #
            if {![ERC:IsConnectedToPG $db $bulkPin $flag]} {
                zmessage print DBG \
                    "      Found result: $bulkPin"
                lappend resList $bulkPin
            }
        }
        if {[zprogress pop]} {
            break
        }
    }
    if {[zprogress pop]} {
        return {}
    }

    ##
    # Return the calculated result.
    #
    return $resList
}