1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
110
###############################################################################
# Copyright (c) 2012-2024 by Altair Engineering, Inc.
# All rights reserved.
#
# Altair Engineering, Inc. makes this software available as part of the Vision
# tool platform.  As long as you are a licensee of the Vision tool platform
# you may make copies of the software and modify it to be used within the
# Vision tool platform, but you must include all of this notice on any copy.
# Redistribution without written permission to any third party, with or
# without modification, is not permitted.
# Altair Engineering, Inc. does not warrant that this software is error free
# or fit for any purpose.  Altair Engineering, Inc. disclaims any liability for
# all claims, expenses, losses, damages and costs any user may incur as a
# result of using, copying or modifying the software.
# =============================================================================
#   @script
#       Check that the gate pin of a MOSFET device is not connected to a power
#       or ground node.
#
#       Algorithm
#           1. Identify all MOS devices in the design.
#           2. Check if the gate pin is connected to a power or ground node.
#           3. Add the devices that violate the above rule to the result list.
#
#       Example
#           demo/api/erc/testcase01.sp
###############################################################################


# =============================================================================
# Check01 -
# =============================================================================
#
proc ERC:Check01 {db} {
    ##
    # Initialize the result list.
    #
    set resList {}

    ##
    # Flag devices in the loaded database.
    #
    zprogress push "" 0.05
    ERC:FlagDevices $db {"NMOS" "PMOS"}
    if {[zprogress pop]} {
        return
    }

    ##
    # Loop over all modules in the loaded design.
    #
    zprogress push "" 1.0
    set mcount [$db count module]
    set m 0
    $db foreach module module {
        zmessage print DBG \
            "Process module [$db oid print $module]"

        zprogress push "" [expr {double([incr m]) / $mcount}]

        ##
        # Loop over all instances in the current module.
        #
        set icount [$db count inst $module]
        set i 0
        $db foreach inst $module inst {
            if {[zprogress update "" [incr i] $icount]} {
                break
            }

            ##
            # Skip all instances where the cell referenced by the instance
            # has the green flag not set.
            #
            if {![$db flag [$db down $inst] is green]} {
                continue
            }
            zmessage print DBG \
                "  Process instance [$db oid print $inst]"

            ##
            # Investigate only the gate pin for connections to power or ground.
            #
            set gatePin [$db getFuncPort $inst -name gate]
            zmessage print DBG \
                "    Process gate pin [$db oid print $gatePin]"

            ##
            # If the gate pin is connected to power or ground then add the
            # gate pin to the result list.
            #
            if {[ERC:IsConnectedToPG $db $gatePin {}]} {
                zmessage print DBG \
                    "      Found result: $gatePin"
                lappend resList $gatePin
            }
        }
        if {[zprogress pop]} {
            break
        }
    }
    if {[zprogress pop]} {
        return {}
    }

    ##
    # Return the calculated result.
    #
    return $resList
}